Leibundgut, G. and Rohner, A. and Grize, L. and Bernheim, A. and Kessel-Schaefer A., and Bremerich, J. and Zellweger, M. and Buser, P. and Handke, M.. (2010) Dynamic assessment of right ventricular volumes and function by real-time three-dimensional echocardiography : a comparison study with magnetic resonance imaging in 100 adult patients. Journal of the American Society of Echocardiography, Vol. 23, H. 2. pp. 116-126.
Full text not available from this repository.
Official URL: http://edoc.unibas.ch/dok/A5842874
Downloads: Statistics Overview
Abstract
BACKGROUND: The aim of this study was to validate a novel real-time three-dimensional echocardiographic (RT3DE) analysis tool for the determination of right ventricular volumes and function in unselected adult patients. METHODS: A total of 100 consecutive adult patients with normal or pathologic right ventricles were enrolled in the study. A dynamic polyhedron model of the right ventricle was generated using dedicated RT3DE software. Volumes and ejection fractions were determined and compared with results obtained on magnetic resonance imaging (MRI) in 88 patients with adequate acquisitions. RESULTS: End-diastolic, end-systolic, and stroke volumes were slightly lower on RT3DE imaging than on MRI (124.0 +/- 34.4 vs 134.2 +/- 39.2 mL, P > .001; 65.2 +/- 23.5 vs 69.7 +/- 25.5 mL, P = .02; and 58.8 +/- 18.4 vs 64.5 +/- 24.1 mL, P > .01, respectively), while no significant difference was observed for ejection fraction (47.8 +/- 8.5% vs 48.2 +/- 10.8%, P = .57). Correlation coefficients on Bland-Altman analysis were r = 0.84 (mean difference, 10.2 mL; 95% confidence interval [CI], -31.3 to 51.7 mL) for end-diastolic volume, r = 0.83 (mean difference, 4.5 mL; 95% CI, -23.8 to 32.9 mL) for end-systolic volume, r = 0.77 (mean difference, 5.7 mL; 95% CI, -24.6 to 36.0 mL) for stroke volume, and r = 0.72 (mean difference, 0.4%; 95% CI, -14.2% to 15.1%) for ejection fraction. CONCLUSION: Right ventricular volumes and ejection fractions as assessed using RT3DE imaging compare well with MRI measurements. RT3DE imaging may become a time-saving and cost-saving alternative to MRI for the quantitative assessment of right ventricular size and function
Faculties and Departments: | 03 Faculty of Medicine > Bereich Querschnittsfächer (Klinik) > Ehemalige Einheiten Querschnittsfächer (Klinik) > Medizinische Radiologie (Steinbrich) 03 Faculty of Medicine > Departement Klinische Forschung > Bereich Querschnittsfächer (Klinik) > Ehemalige Einheiten Querschnittsfächer (Klinik) > Medizinische Radiologie (Steinbrich) 03 Faculty of Medicine > Bereich Medizinische Fächer (Klinik) > Kardiologie 03 Faculty of Medicine > Departement Klinische Forschung > Bereich Medizinische Fächer (Klinik) > Kardiologie 09 Associated Institutions > Swiss Tropical and Public Health Institute (Swiss TPH) > Former Units within Swiss TPH > Infectious Disease Modelling > Epidemiology and Transmission Dynamics (Smith) |
---|---|
UniBasel Contributors: | Bernheim, Alan M. and Bremerich, Jens and Zellweger, Michael J. and Grize, Leticia |
Item Type: | Article, refereed |
Article Subtype: | Research Article |
Publisher: | Mosby/Elsevier |
ISSN: | 0894-7317 |
Note: | Publication type according to Uni Basel Research Database: Journal article |
Related URLs: | |
Identification Number: |
|
Last Modified: | 19 Jul 2013 07:35 |
Deposited On: | 14 Sep 2012 06:52 |
Repository Staff Only: item control page