edoc-vmtest

Intra-operative myocardial ischaemia cannot be detected by analysis of transmitral inflow patterns in patients undergoing off-pump coronary surgery

Wang, J. and Seeberger, M. D. and Skarvan, K. and Michaux, I. and Bernet, F. and Arsenic, R. and Buser, P. and Filipovic, M.. (2008) Intra-operative myocardial ischaemia cannot be detected by analysis of transmitral inflow patterns in patients undergoing off-pump coronary surgery. EJA : European journal of anaesthesiology, Vol. 25. pp. 1-7.

Full text not available from this repository.

Official URL: http://edoc.unibas.ch/dok/A6006652

Downloads: Statistics Overview

Abstract

SummaryBackground and objectiveTransmitral inflow patterns have been used for detection of myocardial ischaemia. However, its diagnostic value has not been tested in anaesthetized and mechanically ventilated patients undergoing coronary artery bypass graft surgery. METHODS: Transmitral inflow patterns were studied by transoesophageal Doppler echocardiography in 43 patients undergoing coronary artery bypass graft surgery without cardiopulmonary bypass after opening of the sternum (baseline) and during grafting of the left anterior descending artery. Peak early (E) and peak late (A) transmitral velocities and their ratio (E/A) were recorded. Myocardial ischaemia was defined by standard criteria using two-dimensional echocardiography and seven-lead electrocardiogram. RESULTS: Thirty-one patients (64 +/- 8 yr, 9 women) fulfilled the predefined inclusion criteria for analysis. During distal revascularization, 16 patients showed myocardial ischaemia and 15 did not. The use of vasoactive drugs, haemodynamic findings and transmitral inflow patterns were similar in both groups at baseline and during grafting. In the ischaemic group, E was 67.1 +/- 13.9 cm s-1 at baseline and 69.5 +/- 23.2 cm s-1 during grafting, and the E/A ratios were 1.3 +/- 0.3 and 1.4 +/- 0.9, respectively. In the non-ischaemic group, E was 64.0 +/- 17.1 cm s-1 at baseline and 60.9 +/- 14.8 cm s-1 during grafting, and the E/A ratios were 1.4 +/- 0.7 and 1.2 +/- 0.3, respectively. CONCLUSIONS: Analysis of Doppler findings of transmitral inflow patterns did not allow for detection of myocardial ischaemia during surgical revascularization of the myocardium.
Faculties and Departments:03 Faculty of Medicine > Bereich Querschnittsfächer (Klinik) > Anästhesiologie
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Querschnittsfächer (Klinik) > Anästhesiologie
03 Faculty of Medicine > Bereich Medizinische Fächer (Klinik) > Kardiologie > Kardiologie (Buser)
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Medizinische Fächer (Klinik) > Kardiologie > Kardiologie (Buser)
UniBasel Contributors:Filipovic, Miodrag and Buser, Peter and Seeberger-Stucky, Manfred
Item Type:Article, refereed
Article Subtype:Research Article
Publisher:Blackwell
Note:Publication type according to Uni Basel Research Database: Journal article
Related URLs:
Identification Number:
Last Modified:08 Nov 2012 16:22
Deposited On:08 Nov 2012 16:12

Repository Staff Only: item control page