edoc-vmtest

Painful knee joint after ACL reconstruction using biodegradable interference screws- SPECT/CT a valuable diagnostic tool? : a case report

Hirschmann, Michael T. and Adler, Tom and Rasch, Helmut and Hügli, Rolf W. and Friederich, Niklaus F. and Arnold, Markus P.. (2010) Painful knee joint after ACL reconstruction using biodegradable interference screws- SPECT/CT a valuable diagnostic tool? : a case report. Sports medicine, arthroscopy, rehabilitation, therapy and technology, Vol. 2. p. 24.

Full text not available from this repository.

Official URL: http://edoc.unibas.ch/dok/A6006252

Downloads: Statistics Overview

Abstract

ABSTRACT: With the presented case we strive to introduce combined single photon emission computerized tomography and conventional computer tomography (SPECT/CT) as new diagnostic imaging modality and illustrate the possible clinical value in patients after ACL reconstruction. We report the case of a painful knee due to a foreign body reaction and delayed degradation of the biodegradable interference screws after ACL reconstruction. The MRI showed an intact ACL graft, a possible tibial cyclops lesion and a patella infera. There was no increased fluid collection within the bone tunnels. The 99mTc-HDP-SPECT/CT clearly identified a highly increased tracer uptake around and within the tibial and femoral tunnels and the patellofemoral joint. On 3D-CT out of the SPECT/CT data the femoral graft attachment was shallow (50% along the Blumensaat's line) and high in the notch. At revision arthroscopy a diffuse hypertrophy of the synovium, scarring of the Hoffa fat pad and a cyclops lesion of the former ACL graft was found. The interference screws were partially degraded and under palpation and pressure a grey fluid-like substance drained into the joint. The interference screws and the ACL graft were removed and an arthrolysis performed.In the case presented it was most likely a combination of improper graft placement, delayed degradation of the interference screws and unknown biological factors. The too shallow and high ACL graft placement might have led to roof impingement, chronic intraarticular inflammation and hence the delayed degradation of the screws.SPECT/CT has facilitated the establishment of diagnosis, process of decision making and further treatment in patients with knee pain after ACL reconstruction. From the combination of structural (tunnel position in 3D-CT) and metabolic information (tracer uptake in SPECT/CT) the patient's cause of the pain was established.
Faculties and Departments:03 Faculty of Medicine > Bereich Operative Fächer (Klinik) > Bewegungsapparat und Integument
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Operative Fächer (Klinik) > Bewegungsapparat und Integument
UniBasel Contributors:Friederich, Niklaus F. and Arnold, Markus P.
Item Type:Article, refereed
Article Subtype:Research Article
Publisher:BioMed Central
Note:Publication type according to Uni Basel Research Database: Journal article
Related URLs:
Identification Number:
Last Modified:08 Nov 2012 16:23
Deposited On:08 Nov 2012 16:17

Repository Staff Only: item control page