Kos, Sebastian and Huegli, Rolf and Hofmann, Eugen and Quick, Harald H. and Kuehl, Hilmar and Aker, Stephanie and Kaiser, Gernot M. and Borm, Paul J. A. and Jacob, Augustinus L. and Bilecen, Deniz. (2009) MR-compatible polyetheretherketone-based guide wire assisting MR-guided stenting of iliac and supraaortic arteries in swine : feasibility study. Minimally invasive therapy & allied technologies, Vol. 18. pp. 181-188.
Full text not available from this repository.
Official URL: http://edoc.unibas.ch/dok/A6003084
Downloads: Statistics Overview
Abstract
The purpose of this study was to demonstrate first magnetic resonance (MR)-guided stenting of iliac and supraaortic arteries using a polyetheretherketone-based (PEEK) MR-compatible guide wire. In vitro and animal experiments were performed in a short magnet wide-bore scanner (1.5 Tesla, Espree, Siemens Healthcare, Erlangen, Germany). For all experiments, a 0.035'' MR-compatible guide wire prototoype was used. This wire had a compound core of PEEK with reinforcing fibres, a soft and atraumatic tip and a hydrophilic coating. For its passive visualization, paramagnetic markings were attached. All experiments were performed through a vascular introducer sheath under MR-guidance. In vitro repetitive selective over the wire catheterizations of either the right carotid artery and the left subclavian artery were performed. In vivo, selective catheterization and over-the-wire stenting of the brachiocephalic trunk and the left subclavian artery were performed. The common iliac arteries were catheterized retrogradely (left) and cross-over (right). Angioplasty and stenting were performed over-the-wire. All procedures were successful. Visibility of the PEEK-based guide-wire was rated good in vitro and acceptable in vivo. Guide wire pushability and endovascular device support were good. The PEEK-based MR-compatible guide wire is well visible and usable under MR-guidance. It supports over-the-wire treatment of iliac arteries and supraaortic arteries.
Faculties and Departments: | 03 Faculty of Medicine > Bereich Querschnittsfächer (Klinik) > Radiologie USB 03 Faculty of Medicine > Departement Klinische Forschung > Bereich Querschnittsfächer (Klinik) > Radiologie USB 03 Faculty of Medicine > Bereich Querschnittsfächer (Klinik) > Ehemalige Einheiten Querschnittsfächer (Klinik) > Medizinische Radiologie (Steinbrich) 03 Faculty of Medicine > Departement Klinische Forschung > Bereich Querschnittsfächer (Klinik) > Ehemalige Einheiten Querschnittsfächer (Klinik) > Medizinische Radiologie (Steinbrich) 03 Faculty of Medicine > Bereich Querschnittsfächer (Klinik) > Ehemalige Einheiten Querschnittsfächer (Klinik) > Interventionelle Radiologie (Jacob) 03 Faculty of Medicine > Departement Klinische Forschung > Bereich Querschnittsfächer (Klinik) > Ehemalige Einheiten Querschnittsfächer (Klinik) > Interventionelle Radiologie (Jacob) |
---|---|
UniBasel Contributors: | Hügli, Rolf and Kos, Sebastian and Jacob, Augustinus Ludwig |
Item Type: | Article, refereed |
Article Subtype: | Research Article |
Publisher: | Taylor & Francis |
ISSN: | 1364-5706 |
Note: | Publication type according to Uni Basel Research Database: Journal article |
Related URLs: | |
Identification Number: |
|
Last Modified: | 01 Mar 2013 11:14 |
Deposited On: | 01 Mar 2013 11:10 |
Repository Staff Only: item control page