edoc-vmtest

Strategies for reducing variance in laser Doppler flowmetry measurements

Pemp, B. and Maar, N. and Weigert, G. and Luksch, A. and Resch, H. and Garhofer, G. and Orgul, S. and Schmetterer, L.. (2009) Strategies for reducing variance in laser Doppler flowmetry measurements. Albrecht von Graefes Archiv für klinische und experimentelle Ophthalmologie = Albrecht von Graefe's archive for clinical and experimental ophthalmology, Vol. 247. pp. 67-71.

Full text not available from this repository.

Official URL: http://edoc.unibas.ch/dok/A6007139

Downloads: Statistics Overview

Abstract

BACKGROUND: Scattering of blood flow data as assessed with laser Doppler flowmetry (LDF) in humans is a problem in many studies using this technique. We set out to reduce variability in LDF data by eliminating the effect of the total returning light level (DC) on LDF parameters in the choroid through partial regression analysis. METHODS: In 20 healthy subjects, choroidal blood flow parameters were measured at different DC values using a portable confocal LDF device. We used two different strategies to reduce scattering of data eliminating the effect of yield, which is defined as DC/gain. On the one hand, we used a previously described method based on a third-order polynomial fit, which combines all obtained data. On the other hand, we applied a new method based on a linear fit for each individual subject. RESULTS: Variability of data during changes in DC is higher for LDF parameters volume and flow than for velocity. Both methods were successful in reducing scattering of LDF parameters with varying DC. CONCLUSIONS: The present study indicates that both methods to correct for changes in yield were successful in reducing the variability of LDF measurements. When systematic changes in DC occur after an intervention, one needs to be careful in interpreting the obtained data and it remains to be shown if either of the two techniques is capable of correcting for this effect. The approach presented here may, however, represent an effective, easily applicable and valid approach to reduce scattering of data from using LDF to assess blood flow in the posterior pole of the human eye.
Faculties and Departments:03 Faculty of Medicine > Bereich Spezialfächer (Klinik) > Ophthalmologie USB > Ophthalmologie (Orgül)
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Spezialfächer (Klinik) > Ophthalmologie USB > Ophthalmologie (Orgül)
UniBasel Contributors:Orgül, Selim
Item Type:Article, refereed
Article Subtype:Research Article
Publisher:Springer
ISSN:0065-6100
Note:Publication type according to Uni Basel Research Database: Journal article
Related URLs:
Identification Number:
Last Modified:24 May 2013 09:22
Deposited On:24 May 2013 09:04

Repository Staff Only: item control page