Accuracy of ventilatory measurement employing ambulatory inductive plethysmography during tasks of everyday life

Grossman, Paul and Wilhelm, Frank H. and Brutsche, Martin. (2010) Accuracy of ventilatory measurement employing ambulatory inductive plethysmography during tasks of everyday life. Biological psychology, Vol. 84, H. 1. pp. 121-128.

Full text not available from this repository.

Official URL: http://edoc.unibas.ch/dok/A6008281

Downloads: Statistics Overview

Abstract

Ambulatory inductive plethysmography (AIP) has recently been introduced to permit monitoring of ventilation outside the clinic and laboratory. It provides a method for nonintrusive assessment of both timing (e.g. respiration rate; RR) and volumetric parameters (e.g. tidal volume and minute ventilation volume; V(T) and V'(E), respectively). Although inductive plethysmography has been validated in laboratory investigations, quantitative validation during ambulatory, naturalistic conditions has not yet been assessed. Should AIP yield accurate estimation of ventilatory parameters, real-life monitoring of breathing pattern may provide new insights into respiratory functioning in health and disease. We examined the accuracy of AIP for assessing RR, V(T) and V'(E) during a 90-min protocol simulating activities of everyday life. A mobile backpack metabolic cart with integrated flowmeter was employed as the reference standard. Within- and between-participant minute-by-minute comparisons were made for each ventilatory measure among 9 healthy adults. Average within-participant minute-by-minute correlations between reference method and AIP were 0.96, 0.91 and 0.92 for V'(E), V(T) and RR, respectively. Average correlations across participants yielded r's of 0.98, 0.98 and 1.0. Analysis of mean task levels across participants revealed, in all cases, very close correspondences between both methods of measurement, with only a significant but minor deviance during a period of supine posture. Additionally, results indicated that within-individual variations in oxygen consumption were highly correlated with AIP-estimated V'(E), suggesting that ambulatory assessment of V'(E) may provide a reliable index of metabolic activity during everyday life.
Faculties and Departments:03 Faculty of Medicine > Bereich Medizinische Fächer (Klinik) > Pneumologie
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Medizinische Fächer (Klinik) > Pneumologie
03 Faculty of Medicine > Bereich Medizinische Fächer (Klinik) > Psychosomatik
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Medizinische Fächer (Klinik) > Psychosomatik
UniBasel Contributors:Brutsche, Martin and Grossmann, Paul
Item Type:Article, refereed
Article Subtype:Further Journal Contribution
Publisher:Elsevier
ISSN:0301-0511
Note:Publication type according to Uni Basel Research Database: Journal item
Related URLs:
Identification Number:
Last Modified:23 May 2014 08:33
Deposited On:23 May 2014 08:33

Repository Staff Only: item control page