edoc-vmtest

Improved renal function and blood pressure control following renal artery angioplasty : the renal artery angioplasty in patients with renal insufficiency and hypertension using a dedicated renal stent device study (PRECISION)

Rastan, Aljoscha and Krankenberg, Hans and Müller-Hülsbeck, Stefan and Sixt, Sebastian and Tübler, Thilo and Müller, Christian and Schwarzwälder, Uwe and Frank, Ulrich and Schwarz, Thomas and Leppaenen, Olli and Neumann, Franz-Josef and Zeller, Thomas. (2008) Improved renal function and blood pressure control following renal artery angioplasty : the renal artery angioplasty in patients with renal insufficiency and hypertension using a dedicated renal stent device study (PRECISION). EuroIntervention, Vol. 4, H. 2. pp. 208-213.

Full text not available from this repository.

Official URL: http://edoc.unibas.ch/dok/A6003702

Downloads: Statistics Overview

Abstract

AIMS: To evaluate the technical performance of a dedicated renal stent device and the clinical outcome. METHODS AND RESULTS: Fifty patients with 55 renal artery stenoses (RAS) <70% (66 +/- 12 years, 58% male) were included in this non-randomised, prospective, multicentre registry. Primary endpoint was the primary patency rate at one year defined as < or =70% as determined by duplex ultrasound. Major secondary endpoints were procedural success, 30 days MACE rate, the impact of the intervention on renal function, blood pressure control, and on B-type natriuretic peptide (BNP) level. Procedural success rate was 100% and 30 days MACE rate was 0%. Restenosis rate (primary endpoint) and target lesion revascularisation rate after 12 months were 3.5% and 1.8%, respectively. After one year estimated glomerular filtration rate increased from 51 +/- 26 ml/min to 61 +/- 28 ml/min (P=0.004). Mean ambulatory blood pressure was reduced from 102 +/- 14 mmHg to 93 +/- 9 mmHg (P=0.001). Mean daily dose of antihypertensive drugs decreased from 3.0 +/- 1.7 to 2.7 +/- 1.4 (P=0.09). Mean BNP decreased from 251 +/- 282 pg/ml to 188 +/- 219 pg/ml (P=0.046) before discharge. CONCLUSIONS: Technical outcome of the tested device is favourable. The impact of the stent revascularisation on renal function and blood pressure control was promising.
Faculties and Departments:03 Faculty of Medicine > Bereich Medizinische Fächer (Klinik) > Ehemalige Einheiten Medizinische Fächer (Klinik) > Stationäre innere Medizin (Schifferli)
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Medizinische Fächer (Klinik) > Ehemalige Einheiten Medizinische Fächer (Klinik) > Stationäre innere Medizin (Schifferli)
UniBasel Contributors:Müller, Christian
Item Type:Article, refereed
Article Subtype:Research Article
Publisher:Europa Ed.
ISSN:1774-024X
Note:Publication type according to Uni Basel Research Database: Journal article
Related URLs:
Identification Number:
Last Modified:23 May 2014 08:33
Deposited On:23 May 2014 08:33

Repository Staff Only: item control page