edoc-vmtest

Impact of cardiac computed tomography of the interatrial septum before pulmonary vein isolation

Kobza, R. and Schoenenberger, A. W. and Cuculi, F. and Zuber, M. and Auf Der Maur, C. and Buhmann, R. and Resink, T. J. and Erne, P.. (2013) Impact of cardiac computed tomography of the interatrial septum before pulmonary vein isolation. Pacing and clinical electrophysiology, Vol. 36, H. 10. pp. 1245-1250.

Full text not available from this repository.

Official URL: http://edoc.unibas.ch/dok/A6338202

Downloads: Statistics Overview

Abstract

BACKGROUND: Multidetector computed tomography (MDCT) may be useful to identify patients with patent foramen ovale (PFO). The aim of this study was to analyze whether a MDCT performed before pulmonary vein isolation reliably detects a PFO that may be used for access to the left atrium. METHODS AND RESULTS: In 79 consecutive patients, who were referred for catheter ablation of symptomatic paroxysmal or persistent atrial fibrillation (AF), the presence of a PFO was explored by MDCT and transesophageal echocardiography (TEE). TEE was considered as the gold standard, and quality of TEE was good in all patients. In 16 patients (20.3%), MDCT could not be used for analysis because of artifacts, mainly because of AF. On TEE, a PFO was found in 15 (23.8%) of the 63 patients with usable MDCT. MDCT detected six PFO of which four were present on TEE. This corresponded to a sensitivity of 26.7%, a specificity of 95.8%, a negative predictive value of 80.7%, and a positive predictive value of 66.7%. The receiver operating characteristics curve of MDCT for the detection of PFO was 0.613 (95% confidence interval 0.493-0.732). CONCLUSIONS: MDCT may detect a PFO before pulmonary isolation. However, presence of AF may lead to artifacts on MDCT impeding a meaningful analysis. Furthermore, in this study sensitivity and positive predictive value of MDCT were low and therefore MDCT was not a reliable screening tool for detection of PFO.
Faculties and Departments:03 Faculty of Medicine > Departement Biomedizin > Further Research Groups at DBM > Signal Transduction (Resink/Erne)
UniBasel Contributors:Resink, Thérèse J. and Erne, Paul
Item Type:Article, refereed
Article Subtype:Research Article
Publisher:Blackwell Futura Publishing
ISSN:0147-8389
Note:Publication type according to Uni Basel Research Database: Journal article
Related URLs:
Identification Number:
Last Modified:10 Apr 2015 09:13
Deposited On:10 Apr 2015 09:13

Repository Staff Only: item control page