Vontobel, J. and Possner, M. and Schutz, P. and Muller, B. and Taramasso, M. and Binder, R. K. and Haueis, S. and Attinger-Toller, A. and Maisano, F. and Nietlispach, F.. (2015) Early safety outcome following transcatheter aortic valve implantation: is the amount of contrast media used a matter of concern? Swiss Medical Weekly, 145. w14238.
Full text not available from this repository.
Official URL: http://edoc.unibas.ch/56942/
Downloads: Statistics Overview
Abstract
QUESTIONS UNDER STUDY: The study objective was to evaluate the impact of the amount of contrast medium used for transcatheter aortic valve implantation (TAVI) on short-term outcome. Patients undergoing TAVI are exposed to repeat contrast medium application both for preprocedural screening and during the TAVI procedure itself. Whether the amount of contrast media is associated with worse outcome is unclear. METHODS: A total of 257 patients were included (median age 82.7 years) and divided into two groups with preserved and reduced kidney function (glomerular filtration rate >60 ml/min/1.73 m2), respectively. Total volume of contrast media administered during and within 5 days prior to TAVI was analysed. A combined early safety endpoint at 30 days was evaluated. RESULTS: The early safety endpoint was reached by 31 patients and acute kidney injury occurred in 22 patients. The median total volume of contrast media administered was 144 ml (interquartile range 81-225 ml). The amount of contrast did not independently predict the early safety endpoint in the overall population (odds ratio [OR] 0.93, 95% confidence interval [CI] 0.56 to 1.53, p = 0.774) and in subgroups with preserved and reduced kidney function. Change in creatinine was an independent strong predictor of the early safety endpoint in the overall population (OR 18.13, 95% CI 4.70 to 69.99, p >0.001), as well as in subgroups with preserved and reduced kidney function. The amount of contrast did not predict a change in creatinine within 72 hours following TAVI (r = 0.02, 95% CI -0.02 to 0.07, p = 0.368). CONCLUSION: Decreased kidney function after TAVI influences outcome. When rather small amounts of contrast media are used for screening and the TAVI procedure itself, the amount of contrast media seems not to be an independent predictor of outcome, further suggesting that decreased kidney function after TAVI is multifactorial.
Faculties and Departments: | 03 Faculty of Medicine > Bereich Medizinische Fächer (Klinik) > Allgemeine innere Medizin AG > Argovia Professur für Medizin (Müller) 03 Faculty of Medicine > Departement Klinische Forschung > Bereich Medizinische Fächer (Klinik) > Allgemeine innere Medizin AG > Argovia Professur für Medizin (Müller) |
---|---|
UniBasel Contributors: | Müller, Beat |
Item Type: | Article, refereed |
Article Subtype: | Research Article |
Publisher: | EMH Schweizerischer Arzteverlag |
ISSN: | 1424-7860 |
e-ISSN: | 1424-3997 |
Note: | Publication type according to Uni Basel Research Database: Journal article |
Identification Number: |
|
Last Modified: | 04 Dec 2017 10:43 |
Deposited On: | 04 Dec 2017 10:43 |
Repository Staff Only: item control page