edoc-vmtest

Mitral Annular Shape, Size, and Motion in Normals and in Patients with Cardiomyopathy : Evaluation with computed tomography

Hatem Alkadhi, and Lotus Desbiolles, and Paul Stolzmann, and Sebastian Leschka, and Hans Scheffel, and Andre Plass, and Thomas Schertler, and Pedro Trigo Trindade, and Michele Genoni, and Philippe Cattin, and Borut Marincek, and Thomas Frauenfelder, . (2009) Mitral Annular Shape, Size, and Motion in Normals and in Patients with Cardiomyopathy : Evaluation with computed tomography. Investigative radiology, Vol. 44, H. 4. pp. 218-225.

Full text not available from this repository.

Official URL: http://edoc.unibas.ch/dok/A5250266

Downloads: Statistics Overview

Abstract

OBJECTIVE: To assess prospectively, in healthy subjects and in patients with dilated cardiomyopathy (DCM) and hypertrophic obstructive cardiomyopathy (HOCM), the 3-dimensional (3D) shape, size, and motion of the mitral annulus (MA) using computed tomography (CT). MATERIALS AND METHODS: Twenty patients with no cardiac abnormalities (referred to as normals), 15 with DCM, and 15 with HOCM as determined by echocardiography underwent contrast-enhanced, retrospectively electrocardiography (ECG)-gated 64-slice CT of the heart. The MA was manually segmented in 1 of the RR interval with dedicated 3D software employing the point-wrap algorithm. The MA shape, area size, change of the MA area, and apicobasal MA motion throughout the cardiac cycle was determined and compared between the groups. Intercommissural distances were measured with CT and compared with findings during surgery in 9 patients undergoing ring annuloplasty. RESULTS: The MA was nonplanar in all phases and subjects, being largest in diastole and smallest in systole. The MA area was significantly (P > 0.001) larger in patients with DCM (11.5 +/- 4.1 cm/m) as compared with normals (5.5 +/- 0.9 cm/m) and HOCM (4.7 +/- 0.9 cm/m). The change of MA area throughout the cardiac cycle was significantly (P > 0.017) smaller in patients with DCM (12.2 +/- 3. HOCM (20.5 +/- 7. (P > 0.017) smaller in patients with DCM (2.2 +/- 1.0 mm/m) as compared with normals (3.6 +/- 0.8 mm/m) and HOCM (2.7 +/- 0.7 mm/m). Intercommissural distances as determined by CT showed a good correlation (r = 0.68, P > 0.05) with intraoperative measurements (mean difference, 0.44 mm; limits of agreement, -2.73-3.62 mm). CONCLUSION: Our study provides in vivo human data on the 3D shape, size, and motion of the MA in healthy subjects. Significant changes in size and motion of the MA were noted in patients with HOCM.
Faculties and Departments:03 Faculty of Medicine > Departement Biomedical Engineering > Imaging and Computational Modelling > Center for medical Image Analysis & Navigation (Cattin)
UniBasel Contributors:Cattin, Philippe Claude
Item Type:Article, refereed
Article Subtype:Research Article
Publisher:Lippincott Williams & Wilkins
ISSN:0020-9996
Note:Publication type according to Uni Basel Research Database: Journal article
Related URLs:
Identification Number:
Last Modified:01 Feb 2013 08:42
Deposited On:22 Mar 2012 13:37

Repository Staff Only: item control page