edoc-vmtest

The n_TOF Total Absorption Calorimeter for neutron capture measurements at CERN

Guerrero, C. and Abbondanno, U. and Aerts, G. and Alvarez, H. and Alvarez-Velarde, F. and Andriamonje, S. and Andrzejewski, J. and Assimakopoulos, P. and Audouin, L. and Badurek, G. and Baumann, P. and Becvar, F. and Berthoumieux, E. and Calvino, F. and Calviani, M. and Cano-Ott, D. and Capote, R. and Carrapico, C. and Cennini, P. and Chepel, V. and Chiaveri, E. and Colonna, N. and Cortes, G. and Couture, A. and Cox, J. and Dahlfors, M. and David, S. and Dillmann, I. and Domingo-Pardo, C. and Dridi, W. and Duran, I. and Eleftheriadis, C. and Ferrant, L. and Ferrari, A. and Ferreira-Marques, R. and Fujii, K. and Furman, W. and Goncalves, I. and Gonzalez-Romero, E. and Gramegna, F. and Gunsing, F. and Haas, B. and Haight, R. and Heil, M. and Herrera-Martinez, A. and Igashira, M. and Jericha, E. and Kaeppeler, F. and Kadi, Y. and Karadimos, D. and Kerveno, M. and Koehler, P. and Kossionides, E. and Krticka, M. and Lampoudis, C. and Leeb, H. and Lindote, A. and Lopes, I. and Lozano, M. and Lukic, S. and Marganiec, J. and Marrone, S. and Martinez, T. and Massimi, C. and Mastinu, P. and Mendoza, E. and Mengoni, A. and Milazzo, P. M. and Moreau, C. and Mosconi, M. and Neves, F. and Oberhummer, H. and O`Brien, S. and Pancin, J. and Papachristodoulou, C. and Papadopoulos, C. and Paradela, C. and Patronis, N. and Pavlik, A. and Pavlopoulos, P. and Perrot, L. and Pigni, M. T. and Plag, R. and Plompen, A. and Plukis, A. and Poch, A. and Praena, J. and Pretel, C. and Quesada, J. and Rauscher, T. and Reifarth, R. and Rubbia, C. and Rudolf, G. and Rullhusen, P. and Salgado, J. and Santos, C. and Sarchiapone, L. and Savvidis, I. and Stephan, C. and Tagliente, G. and Tain, J. L. and Tassan-Got, L. and Tavora, L. and Terlizzi, R. and Vannini, G. and Vaz, P. and Ventura, A. and Villamarin, D. and Vicente, M. C. and Vlachoudis, V. and Vlastou, R. and Voss, F. and Walter, S. and Wiescher, M. and Wisshak, K.. (2009) The n_TOF Total Absorption Calorimeter for neutron capture measurements at CERN. Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, Vol. 608, H. 3. pp. 424-433.

Full text not available from this repository.

Official URL: http://edoc.unibas.ch/dok/A5253859

Downloads: Statistics Overview

Abstract

The n_TOF Collaboration has built and commissioned a high-performance detector for (n, gamma) measurements called the Total Absorption Calorimeter (TAC). The TAC was especially designed for measuring neutron capture cross-sections of low-mass and/or radioactive samples with the accuracy required for nuclear technology and stellar nucleosynthesis. We present a detailed description of the TAC and discuss its overall performance in terms of energy and time resolution, background discrimination, detection efficiency and neutron sensitivity.
Faculties and Departments:05 Faculty of Science > Departement Physik > Former Organization Units Physics > Theoretische Physik Astrophysik (Thielemann)
UniBasel Contributors:Rauscher, Thomas
Item Type:Article, refereed
Article Subtype:Research Article
Publisher:Elsevier
ISSN:0168-9002
Note:Publication type according to Uni Basel Research Database: Journal article
Related URLs:
Identification Number:
Last Modified:22 Mar 2012 14:25
Deposited On:22 Mar 2012 13:47

Repository Staff Only: item control page