Grossman, Paul and Spoerle, Monika and Wilhelm, Frank H.. (2006) Reliability of respiratory tidal volume estimation by means of ambulatory inductive plethysmography. Biomedical Sciences Instrumentation, 42. pp. 193-198.
PDF
Restricted to Repository staff only 62Kb |
Official URL: http://edoc.unibas.ch/dok/A5250335
Downloads: Statistics Overview
Abstract
Ambulatory monitoring of ventilatory parameters in everyday life, field research and clinical situations may offer new insights into respiratory functioning in health and disease. Recent technological advances that employ ambulatory inductive plethysmography could make monitoring of respiration outside the clinic and laboratory feasible. Inductive plethysmography provides a method for nonintrusive assessment of both timing (e.g. respiration rate) and volumetric parameters (e.g. tidal volume and minute ventilation), by which tidal volume is initially calibrated to direct measures of volume. Estimates of tidal volume assessed by this technique have been validated in laboratory investigations, usually examining within-individual relations to direct measures over a large range of tidal volume variation. However, the reliability of individual differences in tidal volume or other breathing parameters has not been tested under naturalistic measurement conditions using inductive plethysmography. We examined the test-retest reliability of respiration rate, tidal volume and other volumetric parameters of breathing over a period of six weeks of repeated measurements during baseline conditions and breathing exercises with 16 healthy freely moving volunteers in a Yoga course. Reliability of measurement was evaluated by calculating the average week-to-week between-subject correlation coefficients for each physiological measure. Additionally because body-mass index has been previously positively correlated to tidal volume, we also assessed this relationship as an external criterion of validity of tidal volume estimation. Regarding the latter, similar correlations to those previous studies were found (r = 0.6). Furthermore, reliability estimates were high and consistent across respiratory measures (typically r's = 0.7-0.8). These results suggest the validity of ambulatory inductive plethysmographic measurement of respiration, at least under relatively sedentary conditions. Findings also point to the stability of individual differences in respiratory parameters over consecutive weeks.
Faculties and Departments: | 07 Faculty of Psychology 07 Faculty of Psychology > Departement Psychologie > Ehemalige Einheiten Psychologie > Abteilung Klinische Psychologie und Psychiatrie 07 Faculty of Psychology > Departement Psychologie > Ehemalige Einheiten Psychologie > Psychophysiologie (Wilhelm) |
---|---|
UniBasel Contributors: | Wilhelm, Frank H |
Item Type: | Article, refereed |
Article Subtype: | Research Article |
Note: | Publication type according to Uni Basel Research Database: Journal article |
Language: | English |
Related URLs: | |
Identification Number: |
|
edoc DOI: | |
Last Modified: | 28 Sep 2017 14:10 |
Deposited On: | 22 Mar 2012 13:49 |
Repository Staff Only: item control page