Browse by Basel Contributors ID
Kuban, Pavel and Hauser, Peter C.. (2017) Contactless conductivity detection for analytical techniques Developments from 2014 to 2016. Electrophoresis, 38 (1). pp. 95-114. Vu, Anh Phuong and Nguyen, Thi Ngan and Do, Thi Trang and Doan, Thu Ha and Ha, Tran Hung and Ta, Thi Thao and Nguyen, Hung Long and Hauser, Peter C. and Nguyen, Thi Anh Huong and Mai, Thanh Duc. (2017) Clinical screening of paraquat in plasma samples using capillary electrophoresis with contactless conductivity detection: Towards rapid diagnosis and therapeutic treatment of acute paraquat poisoning in Vietnam. Journal of Chromatography B, 1060. pp. 111-117. Koenka, Israel Joel and Hauser, Peter C.. (2017) Background conductivity independent counter flow preconcentration method for capillary electrophoresis. Electrophoresis, 38 (21). pp. 2721-2724. Petruci, Joao Flavio da Silveira and Liebetanz, Michael G. and Cardoso, Arnaldo Alves and Hauser, Peter C.. (2017) Absorbance detector for high performance liquid chromatography based on a deep-UV light-emitting diode at 235 nm. Journal of Chromatography A, 1512. pp. 143-146. Bui, Duy Anh and Kraiczek, Karsten G. and Hauser, Peter C.. (2017) Molecular absorption measurements with an optical fibre coupled array of ultra-violet light-emitting diodes. Analytica Chimica Acta, 986. pp. 95-100. Nguyen, Thi Anh Huong and Nguyen, Van Ri and Le, Duc Dung and Nguyen, Thi Thanh Binh and Cao, Van Hoang and Nguyen, Thi Kim Dung and Sáiz, Jorge and Hauser, Peter C. and Mai, Thanh Duc. (2016) Simultaneous determination of rare earth elements in ore and anti-corrosion coating samples using a portable capillary electrophoresis instrument with contactless conductivity detection. Journal of Chromatography A, 1457. pp. 151-158. Mai, Thanh Duc and Le, Minh Duc and Sáiz, Jorge and Duong, Hong Anh and Koenka, Israel Joel and Pham, Hung Viet and Hauser, Peter C.. (2016) Triple-channel portable capillary electrophoresis instrument with individual background electrolytes for the concurrent separations of anionic and cationic species. Analytica Chimica Acta, 911. pp. 121-128. Koenka, Israel Joel and Sáiz, Jorge and Rempel, Paul and Hauser, Peter C.. (2016) Microfluidic Breadboard Approach to Capillary Electrophoresis. Analytical Chemistry, 88 (7). pp. 3761-3767. Koenka, Israel Joel and Mai, Thanh Duc and Hauser, Peter C. and Sáiz, Jorge . (2016) Simultaneous separation of cations and anions in capillary electrophoresis - recent applications. Analytical Methods, 8 (7). pp. 1452-1456. Hauser, Peter C.. (2016) Determination of Alkali Ions in Biological and Environmental Samples. In: Alkali Metal Ions: Their Role for Life. Berlin, pp. 11-25. Caslavska, Jitka and Koenka, Israel Joel and Hauser, Peter C. and Thormann, Wolfgang . (2016) Validation of CE modeling with a contactless conductivity array detector. Electrophoresis, 37 (5-6). pp. 699-710. Bui, Duy Anh and Hauser, Peter C.. (2016) A deep-UV light-emitting diode-based absorption detector for benzene, toluene, ethylbenzene, and the xylene compounds. Sensors and Actuators B: Chemical, 235. pp. 622-626. Koenka, Israel Joel and Kung, Nina and Kuban, Pavel and Chwalek, Thomas and Furrer, Gerhard and Wehrli, Bernhard and Muller, Beat and Hauser, Peter C.. (2016) Thermostatted dual-channel portable capillary electrophoresis instrument. Electrophoresis, 37 (17-18). pp. 2368-2375. Torres, Natascha T. and Steinsberger, Thomas and Droz-Georget, Helen and Muller, Beat and Brandl, Helmut and Hauser, Peter C. and Furrer, Gerhard. (2016) A Novel Method to Quantify Bioavailable Elements and Mobile ATP on Rock Surfaces and Lichens. AIMS Geosciences, 2 (3). pp. 245-258. Vontobel, S. F. and Abad-Villar, E. M. and Kaufmann, C. and Zinkernagel, A. S. and Hauser, P. C. and Thiel, M. A.. (2015) Corneal Penetration of Polyhexamethylene Biguanide and Chlorhexidine Digluconate. Journal of Clinical & Experimental Ophthalmology. p. 1000430. Seitz, P. and Senesky, D. G. and Schoning, M. J. and Hauser, P. C. and Moser, R. and Herzig, H. P. and Melesse, A. M. and Broderick, P. A. and Eugster, P. T.. (2015) 4th International Symposium on Sensor Science (I3S2015): Conference Report. Sensors, 15 (9). pp. 24458-24465. Saiz, J. and Koenka, I. J. and Garcia-Ruiz, C. and Muller, B. and Chwalek, T. and Hauser, P. C.. (2015) Micro-injector for capillary electrophoresis. Electrophoresis, 36 (16). pp. 1941-1944. Nguyen, H. T. A. and Pham, T. N. M. and Ta, T. T. and Nguyen, X. T. and Nguyen, T. L. and Le, T. H. H. and Koenka, I. J. and Sáiz, J. and Hauser, P. C. and Mai, T. D.. (2015) Screening determination of four amphetamine-type drugs in street-grade illegal tablets and urine samples by portable capillary electrophoresis with contactless conductivity detection. Science & justice, 55 (6). pp. 481-486. Kuban, P. and Hauser, P. C.. (2015) Contactless conductivity detection for analytical techniques-Developments from 2012 to 2014. Electrophoresis, 36 (1). pp. 195-211. Koenka, Israel Joel and Sáiz, Jorge and Hauser, Peter C.. (2015) Instrumentino: An Open-Source Software for Scientific Instruments. Chimia, 69 (4). pp. 172-175. Duong, H. A. and Le, M. D. and Nguyen, K. D. M. and Hauser, P. C. and Pham, H. V. and Mai, T. D.. (2015) In-house-made capillary electrophoresis instruments coupled with contactless conductivity detection as a simple and inexpensive solution for water analysis: a case study in Vietnam. Environmental Science: Processes & Impacts, 17 (11). pp. 1941-1951. Bui, Duy Anh and Hauser, Peter C.. (2015) Deep UV-LED Based Absorbance Detectors for Narrow-Bore HPLC and Capillary Electrophoresis. Chimia, 69 (12). p. 806. Bui, Duy Anh and Hauser, Peter C.. (2015) Absorbance detector for capillary electrophoresis based on light-emitting diodes and photodiodes for the deep-ultraviolet range. Journal of Chromatography A, 1421. pp. 203-208. Bui, D. A. and Hauser, P. C.. (2015) Analytical devices based on light-emitting diodes – a review of the state-of-the-art. Analytica chimica acta, 853. pp. 46-58. Sáiz, J. and Mai, T. D. and Koenka, I. J. and Martín-Alberca, C. and Hauser, P. C. and García Ruiz, C.. (2014) Concurrent determination of anions and cations in consumer fireworks with a portable dual-capillary electrophoresis system. Journal of chromatography A, Vol. 1372. pp. 245-252. Nguyen, T. A. H. and Pham, T. N. M. and Doan, T. T. and Ta, T. T. and Saiz, J. and Nguyen, T. Q. H. and Hauser, P. C. and Mai, T. D.. (2014) Simple semi-automated portable capillary electrophoresis instrument with contactless conductivity detection for the determination of beta-agonists in pharmaceutical and pig-feed samples. Journal of chromatography A, Vol. 1360. pp. 305-311. Koenka, I. J. and Sáiz, J. and Hauser, P. C.. (2014) Instrumentino: An open-source modular Python framework for controlling Arduino based experimental instruments. Computer physics communications, Vol. 185, H. 10. pp. 2724-2729. Saiz, Jorge and Koenka, Israel Joel and Thanh Duc Mai, and Hauser, Peter C. and Garcia-Ruiz, Carmen. (2014) Simultaneous separation of cations and anions in capillary electrophoresis. Trends in Analytical Chemistry, 62. pp. 162-172. See, H. H. and Hauser, P.. (2014) Automated Electric-Field-Driven Membrane Extraction System Coupled to Liquid Chromatography-Mass Spectrometry. Analytical chemistry, Vol. 86, H. 17. pp. 8665-8670. Pham, T. T. T. and Mai, T. D. and Nguyen, T. D. and Sáiz, J. and Pham, H. V. and Hauser, P. C.. (2014) Automated dual capillary electrophoresis system with hydrodynamic injeciton for the concurrent determination of cations and anions. Analytica chimica acta, Vol. 841. pp. 77-83. Torres, N. T. and Och, L. M. and Hauser, P. C. and Furrer, G. and Brandl, H. and Vologina, E. and Sturm, M. and Bürgmann, H. and Müller, B.. (2014) Early diagenetic processes generate iron and manganese oxide layers in the sediments of Lake Baikal, Siberia. Environmental Science : processes & impacts, Vol. 16, H. 4. pp. 879-889. Stojkovic, M. and Koenka, I. J. and Thormann, W. and Hauser, P. C.. (2014) Contactless conductivity detector array for capillary electrophoresis. Electrophoresis, Vol. 35, H. 4. pp. 482-486. See, H. H. and Hauser, P. C.. (2014) Electro-driven extraction of low levels of lipophilic organic anions and cations across plasticized cellulose triacetate membranes : effect of the membrane composition. Journal of membrane science, Vol. 450. pp. 147-152. Torres, N. T. and Hauser, P. C. and Furrer, G. and Brandl, H. and Muller, B.. (2013) Sediment porewater extraction and analysis combining filter tube samplers and capillary electrophoresis. Environmental Science, Vol. 15, H. 4. pp. 715-720. Stojkovic, M. and Uda, N. R. and Brodmann, P. and Hauser, P. C.. (2013) Determination of PCR Products by Capillary Electrophoresis with Contactless Conductivity Detection. Chimia, 67 (6). p. 428. Stojkovic, M. and Mai, T. D. and Hauser, P. C.. (2013) Determination of artificial sweeteners by capillary electrophoresis with contactless conductivity detection optimized by hydrodynamic pumping. Analytica chimica acta, Vol. 787. pp. 254-259. Stojkovic, M. and Schlensky, B. and Hauser, P. C.. (2013) Referenced Capacitively Coupled Conductivity Detector for Capillary Electrophoresis. Electroanalysis, Vol. 25, no. 12. pp. 2645-2650. See, H. H. and Stratz, S. and Hauser, P. C.. (2013) Electro-driven extraction across a polymer inclusion membrane in a flow-through cell. Journal of chromatography A, Vol. 1300. pp. 79-84. Schmidt-Marzinkowski, J. and See, H. H. and Hauser, P. C.. (2013) Electric Field Driven Extraction of Inorganic Anions Across a Polymer Inclusion Membrane. Electroanalysis, Vol. 25, no. 8. pp. 1879-1886. Saiz, J. and Mai, T. D. and Lopez, M. L. and Bartolome, C. and Hauser, P. C. and Garcia-Ruiz, C.. (2013) Rapid determination of scopolamine in evidence of recreational and predatory use. Science & justice, Vol. 53, H. 4. pp. 409-414. Saiz, J. and Mai, T. D. and Hauser, P. C. and Garcia-Ruiz, C.. (2013) Determination of nitrogen mustard degradation products in water samples using a portable capillary electrophoresis instrument. Electrophoresis, Vol. 34, H. 14. pp. 2078-2084. Mai, T. D. and Pham, T. T. T. and Pham, H. V. and Saiz, J. and Ruiz, C. G. and Hauser, P. C.. (2013) Portable Capillary Electrophoresis Instrument with Automated Injector and Contactless Conductivity Detection. Analytical chemistry, Vol. 85, H. 4. pp. 2333-2339. Mai, T. D. and Hauser, P. C.. (2013) Study on the interrelated effects of capillary diameter, background electrolyte concentration, and flow rate in pressure assisted capillary electrophoresis with contactless conductivity detection. Electrophoresis, Vol. 34, H. 12. pp. 1796-1803. Kuban, P. and Hauser, P. C.. (2013) Contactless conductivity detection for analytical techniques : developments from 2010 to 2012. Electrophoresis, Vol. 34, H. 1. pp. 55-69. Kamaruzaman, S. and Hauser, P. C. and Sanagi, M. M. and Ibrahim, W. A. W. and Endud, S. and See, H. H.. (2013) A simple microextraction and preconcentration approach based on a mixed matrix membrane. Analytica chimica acta, Vol. 783. pp. 24-30. Bui, D. A. and Hauser, P. C.. (2013) Absorbance measurements with light-emitting diodes as sources: Silicon photodiodes or light-emitting diodes as detectors? Talanta, Vol. 116. pp. 1073-1078. Bui, D. A. and Bomastyk, B. and Hauser, P. C.. (2013) Absorbance detector based on a deep UV light emitting diode for narrow-column HPLC. Journal of separation science, Vol. 36, H. 19. pp. 3152-3157. Buglione, L. and See, H. H. and Hauser, P. C.. (2013) Rapid separation of fatty acids using a poly(vinyl alcohol) coated capillary in nonaqueous capillary electrophoresis with contactless conductivity detection. Electrophoresis, Vol. 34, H. 14. pp. 2072-2077. Buglione, L. and See, H. H. and Hauser, P. C.. (2013) Study on the effects of electrolytes and solvents in the determination of quaternary ammonium ions by nonaqueous capillary electrophoresis with contactless conductivity detection. Electrophoresis, Vol. 34, H. 2. pp. 317-323. Ansari, K. and Ying, J. Y. S. and Hauser, P. C. and de Rooij, N. F. and Rodriguez, I.. (2013) A portable lab-on-a-chip instrument based on MCE with dual topbottom capacitive coupled contactless conductivity detector in replaceable cell cartridge. Electrophoresis, Vol. 34, H. 9-10. pp. 1390-1399. Mantim, T. and Nacapricha, D. and Wilairat, P. and Hauser, P. C.. (2012) Enantiomeric separation of some common controlled stimulants by capillary electrophoresis with contactless conductivity detection. Electrophoresis, Vol. 33, H. 2. pp. 388-394. Pham, T. T. T. and See, H. H. and Morand, R. and Krahenbuhl, S. and Hauser, P. C.. (2012) Determination of free and total valproic acid in human plasma by capillary electrophoresis with contactless conductivity detection. Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, Vol. 907. pp. 74-78. See, Hong Heng and Schmidt-Marzinkowski, Julia and Pormsila, Worapan and Morand, Réjane and Krähenbühl, Stephan and Hauser, Peter C.. (2012) Determination of creatine and phosphocreatine in muscle biopsy samples by capillary electrophoresis with contactless conductivity detection. Analytica Chimica Acta, 727. pp. 78-82. Stojkovic, M. and Uda, N. R. and Brodmann, P. and Popovic, M. and Hauser, P. C.. (2012) Determination of PCR products by CE with contactless conductivity detection. Journal of separation science, Vol. 35, H. 24. pp. 3509-3513. Mai, T. D. and Bomastyk, B. and Duong, H. A. and Pham, H. V. and Hauser, P. C.. (2012) Automated capillary electrophoresis with on-line preconcentration by solid phase extraction using a sequential injection manifold and contactless conductivity detection. Analytica Chimica Acta, Vol. 727. pp. 1-7. Mai, T. D. and Hauser, P. C.. (2012) Simultaneous separations of cations and anions by capillary electrophoresis with contactless conductivity detection employing a sequential injection analysis manifold for flexible manipulation of sample plugs. Journal of chromatography A, Vol. 1267. pp. 266-272. Mai, T. D. and Hauser, P. C.. (2012) Contactless conductivity detection for electrophoretic microseparation techniques. The chemical record, Vol. 12, H. 1. pp. 106-113. Pormsila, Worapan and Morand, Réjane and Krähenbühl, Stephan and Hauser, Peter C.. (2011) Capillary electrophoresis with contactless conductivity detection for the determination of carnitine and acylcarnitines in clinical samples. Journal of Chromatography B, 879 (13-14). pp. 921-926. See, H. H. and Hauser, P. C.. (2011) Electric Field-Driven Extraction of Lipophilic Anions across a Carrier-Mediated Polyme Inclusion Membrane. Analytical chemistry, Vol. 83, H. 19. pp. 7507-7513. Mai, T. D. and Hauser, P. C.. (2011) Pressure-assisted capillary electrophoresis for cation separations using a sequential injection analysis manifold and contactless conductivity detection. Talanta, Vol. 84, H. 5. pp. 1228-1233. Bomastyk, B. and Petrovic, I. and Hauser, P. C.. (2011) Absorbance detector for high-performance liquid chromatography based on light-emitting diodes for the deep-ultraviolet range. Journal of chromatography A, Vol. 1218, H. 24. pp. 3750-3756. Mai, T. D. and Hauser, P. C.. (2011) Anion separations with pressure-assisted capillary electrophoresis using a sequential injection analysis manifold and contactless conductivity detection. Electrophoresis, Vol. 32, H. 21. pp. 3000-3007. Kubáň, P. and Hauser, P. C.. (2011) Capacitively coupled contactless conductivity detection for microseparation techniques - recent developments. Electrophoresis, Vol. 32, H. 1. pp. 30-42. Pormsila, Worapan and Morand, Réjane and Krähenbühl, Stephan and Hauser, Peter C.. (2011) Quantification of plasma lactate concentrations using capillary electrophoresis with contactless conductivity detection. Electrophoresis, 32 (8). pp. 884-889. Lau, H. F. and Quek, N. M. and Law, W. S. and Zhao, J. H. and Hauser, P. C. and Li, S. F. Y.. (2011) Optimization of separation of heavy metals by capillary electrophoresis with contactless conductivity detection. Electrophoresis, 32 (10). pp. 1190-1194. Guijt, R. M. and Armstrong, J. P. and Candish, E. and Lefleur, V. and Percey, W. J. and Shabala, S. and Hauser, P. C. and Breadmore, M. C.. (2011) Microfluidic chips for capillary electrophoresis with integrated electrodes for capacitively coupled conductivity detection based on printed circuit board technology. Sensors and Actuators B: Chemical, 159 (1). pp. 307-313. Pormsila, W. and Krähenbühl, S. and Hauser, P. C.. (2010) Determination of carnitine in food and food supplements by capillary electrophoresis with contactless conductivity detection. Electrophoresis, Vol. 31. pp. 2186-2191. Thanh, D. M. and Schmid, S. and Müller, B. and Hauser, P. C.. (2010) Capillary electrophoresis with contactless conductivity detection coupled to a sequential injection analysis manifold for extended automated monitoring applications. Analytica Chimica Acta, Vol. 665, H. 1. pp. 1-6. See, H. H. and Hauser, P. C. and Sanagi, M. M. and Ibrahim, W. A. W.. (2010) Dynamic supported liquid membrane tip extraction of glyphosate and aminomethylphosphonic acid followed by capillary electrophoresis with contactless conductivity detection. Journal of chromatography A, Vol. 1217, H. 37. pp. 5832-5838. See, H. H. and Hauser, P. C. and Ibrahim, W. A. W. and Sanagi, M. M.. (2010) Rapid and direct determination of glyphosate, glufosinate, and aminophosphonic acid by online preconcentration CE with contactless conductivity detection. Electrophoresis, Vol. 31, H. 3. pp. 575-582. Schuchert-Shi, A. and Hauser, P. C.. (2010) Following the Lipase Catalyzed Enantioselective Hydrolysis of Amino Acid Esters with Capillary Electrophoresis Using Contactless Conductivity Detection. Chirality, Vol. 22, H. 3. pp. 331-335. Ryvolova, M. and Preisler, J. and Foret, F. and Hauser, P. C. and Krasensky, P. and Paull, B. and Macka, M.. (2010) Combined Contactless Conductometric, Photometric, and Fluorimetric Single Point Detector for Capillary Separation Methods. Analytical chemistry, Vol. 82, H. 1. pp. 129-135. Pormsila, W. and Gong, X. Y. and Hauser, P. C.. (2010) Determination of the enantiomers of alpha-hydroxy- and alpha-amino acids in capillary electrophoresis with contactless conductivity detection. Electrophoresis, Vol. 31. pp. 2044-2048. Mahabadi, K. A. and Rodriguez, I. and Lim, C. Y. and Maurya, D. K. and Hauser, P. C. and de Rooij, N. F.. (2010) Capacitively coupled contactless conductivity detection with dual top-bottom cell configuration for microchip electrophoresis. Electrophoresis, Vol. 31, H. 6. pp. 1063-1070. Hauser, P. C.. (2010) Analytical Sciences. Chimia, 64 (12). pp. 871-873. Mai, T. D. and Pham, H. V. and Hauser, P. C.. (2009) Capillary electrochromatography with contactless conductivity detection for the determination of some inorganic and organic cations using monolithic octadecylsilica columns. Analytica Chimica Acta, Vol. 653, pp. 228-233. Pormsila, W. and Krahenbuhl, S. and Hauser, P. C.. (2009) Capillary electrophoresis with contactless conductivity detection for uric acid determination in biological fluids. Analytica Chimica Acta, Vol. 636, pp. 224-228. Schuchert-Shi, A. and Hauser, P. C.. (2009) Study of acetylcholinesterase inhibitors using CE with contactless conductivity detection. Electrophoresis, Vol. 30, H. 19. pp. 3442-3448. Kubáň, P. and Hauser, P. C.. (2009) Fundamentals of electrochemical detection techniques for CE and MCE. Electrophoresis, Vol. 30, H. 19. pp. 3305-3314. Kubáň, P. and Hauser, P. C.. (2009) Ten years of axial capacitively coupled contactless conductivity detection for CZE : a review. Electrophoresis, Vol. 30, H. 1. pp. 176-188. Schuchert-Shi, A. and Hauser, P. C.. (2009) Peptic and tryptic digestion of peptides and proteins monitored by capillary electrophoresis with contactless conductivity detection. Analytical Biochemistry, Vol. 387, H. 2. pp. 202-207. Krčmová, L. and Stjernlof, A. and Mehlen, S. and Hauser, P. C. and Abele, S. and Paull, B. and Macka, M.. (2009) Deep-UV-LEDs in photometric detection: a 255 nm LED on-capillary detector in capillary electrophoresis. The analyst, 134. pp. 2394-2396. Xu, Li and Hauser, Peter C. and Lee, Hian Kee. (2009) Determination of nerve agent degradation products by capillary electrophoresis using field-amplified sample stacking injection with the electroosmotic flow pump and contactless conductivity detection. Journal of Chromatography A, 1216 (31). pp. 5911-5916. Gong, Xiao Yang and Dobrunz, Dorninik and Kumin, Michael and Wiesner, Markus and Revell, Jefferson D. and Wennemers, Helma and Hauser, Peter C.. (2008) Separating stereoisomers of di-, tri-, and tetrapeptides using capillary electrophoresis with contactless conductivity detection. Journal of Separation Science, 31 (3). pp. 565-573. Kuban, Pavel and Kuban, Petr and Kuban, Vlastimil and Hauser, Peter C. and Bocek, Petr. (2008) Capillary electrochromatography of inorganic cations in open tubular columns with a controllable capacity multilayered stationary phase architecture. Journal of chromatography A, 1190 (1-2). pp. 377-382. Schuchert-Shi, Aiping and Hauser, Peter C.. (2008) Monitoring the enzymatic conversion of urea to ammonium by conventional or microchip capillary electrophoresis with contactless conductivity detection. Analytical Biochemistry, 376 (2). pp. 262-267. Schmid, Stefan and Macka, Mirek and Hauser, Peter C.. (2008) UV-absorbance detector for HPLC based on a light-emitting diode. Analyst, 133 (4). pp. 465-469. Quek, Ngee Mien and Law, Wai Siang and Lau, Hiu Fung and Zhao, Jian Hong and Hauser, Peter C. and Li, Sam Fong Yau. (2008) Determination of pharmaceuticals classified as emerging pollutants using capillary electrophoresis with capacitively coupled contactless conductivity detection. Electrophoresis, 29 (17). pp. 3701-3709. Xu, Li and Gong, Xiao Yang and Lee, Hian Kee and Hauser, Peter C.. (2008) Ion-pair liquid-liquid-liquid microextraction of nerve agent degradation products followed by capillary electrophoresis with contactless conductivity detection. Journal of Chromatography A, 1205 (1-2). pp. 158-162. Gong, Xiao Yang and Kuban, Pavel and Scholer, Andre and Hauser, Peter C.. (2008) Determination of gamma-hydroxybutyric acid in clinical samples using capillary electrophoresis with contactless conductivity detection. Journal of Chromatography A, 1213 (1). pp. 100-104. Xu, Li and Hauser, Peter C. and Lee, Hian Kee. (2008) Electro membrane isolation of nerve agent degradation products across a supported liquid membrane followed by capillary electrophoresis with contactless conductivity detection. Journal of Chromatography A, 1214 (1-2). pp. 17-22. Kuban, Pavel and Hauser, Peter C.. (2008) Evaluation of microchip capillary electrophoresis with external contactless conductivity detection for the determination of major inorganic ions and lithium in serum and urine samples. Lab on a Chip, 8 (11). pp. 1829-1836. Kuban, Pavel and Hauser, Peter C.. (2008) A review of the recent achievements in capacitively coupled contactless conductivity detection. Analytica Chimica Acta, 607. pp. 15-29. Schmid, Stefan and Macka, Mirek and Hauser, Peter C.. (2008) Deep-UV Detector for HPLC with Light-Emitting Diode. Chimia, 62 (10). p. 860. Gillespie, Eoin and Connolly, Damian and Macka, Mirek and Hauser, Peter and Paull, Brett. (2008) Development of a contactless conductivity detector cell for 1.6 mm OD (1/16th inch) HPLC tubing and micro-bore columns with on-column detection. Analyst, 133 (8). pp. 1104-1110. |